Bipolar current measuring module

The MCM-I08AII-BI hardware module handles time-synchronous voltage measurements on up to eight channels. Individually configurable measuring channels are electrically isolated and feature integrated signal conditioning.

  • Eight current measuring channels
  • Simultaneous acquisition of all measurement channels
  • Scan rate up to 1ksps
  • Each channel electrically isolated
  • Up to ±50A
  • Self detection of current direction
  • Measurement resolution in micro ampere, depending on measurement range
  • Per-channel measurement range selection
  • Integrated signal conditioning, digitalization, and measurement value processing
  • Power saving mode disables unused channels
Item Wert
Number of channels 8
Measurement resolution 15 Bit
Scan rate per channel 1 ksps
Measurement range ± 50 A
Resolution 0,5 μA to 2mA, depending on used shunt
Permanent isolation voltage (chn-to-chn) max 800V DC
Permanent isolation voltage (chn-to-GND) max 200V DC; max 800V DC when installed in "MCM-BaseRack Isolated"
Bedingung Wert
Operating temperature 0°C to +50°C (32°F to 122°F)
Storage temperature -20°C to +70°C (-4°F to 158°F)
Relative humidity (non-condensing) 20 % to 85 %
International Protection Rating IP20, to EN 60 529 / NEMA 1 enclosure rating

Speed ​​measurement 2-channel

The MCM-S02FII module is ideal for evaluating various Inkrementalgebertypen in systems of process engineering, test stands, test equipment, and HIL systems.

It is the best possible way equipped for use in harsh environments. Application areas include starter test benches, engine test stands, test stands generator and HIL systems.

  • Two digital incremental encoder inputs
  • Simultaneous evaluation of the two measurement channels
  • Speed measurement, angle measurement, distance measurement
  • Galvanic decoupling of each channel
  • Power per sensor
  • Analysis of noise
  • Integrated signal conditioning
Item Wert
Number of channels: ≤ 2
Size: 19" plug-in-module 100x100 mm
In-/output value: Increments
In-/output area: ≤ 1 Mhz
Data rate: < 10 ksps
Precision: ±0,1 %
Resolution: 16 Bit
Bedingung Wert
Operating temperature: 0 ... +50 °C
Storage temperature: -20 ... +70 °C
Relative humidity: 20 ... 85 %
Protection type: IP20 according to EN 60529

Voltage measuring 8-channel

The MCM-U08AII module is ideal for measuring unipolar voltages in test systems and test systems. Use the module to monitor the voltage of the fuel cell, battery stacks, lithium-based batteries and electrolyzers.

It is the best possible way equipped for use in harsh environments. Application areas include Starts test benches, engine test stands, test stands generator, HIL systems and test benches for the conditioning of batteries.

  • Eight voltage measurement channels
  • Simultaneous recording of all channels
  • Sampling rate up to 10 kHz
  • Galvanic decoupling each channel
  • 0 V to 100 V DC voltage measurement
  • <100 µV measurement resolution
  • Range selection individually per channel
  • Integrated signal conditioning
  • Power reduction by switching off unneeded channels
  • Software filters
Item Wert
Number of channels: ≤ 8
Size: 19" plug-in-module 100x100 mm
Isolation voltage: ≤ 800 V
In-/output value: Voltage
In-/output area: 0 ... 100 V
Data rate: < 10 ksps
Precision: ±0,1 %
Resolution: 16 Bit
Bedingung Wert
Operating temperature: 0 ... +50 °C
Storage temperature: -20 ... +70 °C
Relative humidity: 20 ... 85 %
Protection type: IP20 nach EN 60529

Voltage measuring 8-channel bi

The MCM-U08AII-BI module is ideal for measuring bipolar voltages in test systems and test systems. Use the module to monitor the voltage of the fuel cell, battery stacks, lithium-based batteries and electrolyzers.

It is the best possible way equipped for use in harsh environments. Application areas include Starts test benches, engine test stands, test stands generator, HIL systems and test benches for the conditioning of batteries.

  • Eight current measurement channels
  • Simultaneous recording of all channels
  • Sampling rate up to 1 ksps
  • Galvanic decoupling of each channel
  • Automatic detection of current direction
  • measurement resolution depends on the measurement range or shunt in the microampere range
  • Range selection via shunt individually configurable per channel
  • Integrated signal conditioning, digitization and processing of measured values
  • Power reduction by switching off unneeded channels
  • Software filters
Item Wert
Number of channels: ≤ 8
Size: 19" plug-in-module 100x100 mm
Isolation voltage: ≤ 800 V
In-/output value: Current
In-/output area: 0 ... +/-50 V
Data rate: < 10 ksps
Precision: ±0,1 %
Resolution: 15 Bit
Bedingung Wert
Operating temperature: 0 ... +50 °C
Storage temperature: -20 ... +70 °C
Relative humidity: 20 ... 85 %
Protection type: IP20 according to EN 60529

Temperature measurement 8-channel PT

The MCM-T08AII-PT module is ideal for measuring temperatures with temperature sensors PT100/PT1000 in crash-test systems, where a decoupling between metrology and test specimen must be ensured.

It is the best possible way equipped for use in harsh environments. Application areas include starter test benches, engine test stands or generator test stands, HIL systems and test benches for the conditioning of batteries.

  • Eight temperature measurement channels
  • Thermocouple PT100 or PT1000
  • 2-, 3- or 4-wire measurement selectable per channel
  • -80 ° C ... 300 ° C temperature measurement
  • 0.01 K measurement Resolution
  • Accuracy ± 0.1 K in the range -70 ° C to +250 ° C
  • Accuracy ± 0.2 K in the range -80 ° C to +300 ° C (4-wire)
  • Simultaneous acquisition of all channels
  • Sampling internally 500 Hz
  • Output Speed 1, 10, 100 Hz via CAN or SPI
  • Galvanic decoupling of each channel
  • Integrated signal conditioning, digitization and processing of measured values
  • Power reduction by switching off unnecessary channels
  • Software filters
Item Wert
Number of channels: ≤ 8
Size: 19" plug-in-module 100x100 mm
Isolation voltage: ≤ 800 V
In-/output value: Temperature
In-/output area: -80 °C ... +300 °C
Data rate: < 500 sps
Precision: ±0,1 K
Resolution: ±0,01 K
Bedingung Wert
Operating temperature: 0 ... +50 °C
Storage temperature: -20 ... +70 °C
Relative humidity: 20 ... 85 %
Protection type: IP20 according to EN 60529

Temperature measurement 8-channel TE

The MCM-T08AII-TE module is ideal for measuring temperatures with thermocouples in test systems, where a decoupling between metrology and test specimen must be ensured.

It is the best possible way equipped for use in harsh environments. Application areas include starter test benches, engine test stands or generator test stands, HIL systems and test benches for the conditioning of batteries.

  • Eight temperature-measuring channels
  • Simultaneous recording of all channels
  • Sampling rates up to 100 Hz
  • Galvanic decoupling of each channel
  • -40 ° C ... 800 ° C Temperature measurement
  • 0.1 K measurement resolution
  • Integrated signal conditioning, digitization and processing of measured values
  • Automatic Contact breakage detection
  • Power reduction by switching off unneeded channels
  • Software filters
Item Wert
Number of channels: ≤ 8
Size: 19" plug-in-module 100x100 mm
Isolation voltage: ≤ 800 V
In-/output value: Temperature
In-/output area: -40 °C ... +800 °C
Data rate: < 100 sps
Precision: ±1 K
Resolution: 16 Bit
Bedingung Wert
Operating temperature: 0 ... +50 °C
Storage temperature: -20 ... +70 °C
Relative humidity: 20 ... 85 %
Protection type: IP20 according to EN 60529