COMPONENTS FOR CONDITIONING

The conditioning assemblies serve to convert electrical signals so that they can be used for the instruments to which they are connected.

The shunt carrier cards convert currents into voltage values that can be detected with the MCM-I08AII-BI board. Depending on the expected current intensity, they can be equipped with different measuring resistors.

Carrier card for NAW1 modules

The MCM-S02ABS assembly serves as a carrier card for the two NAW1 modules Inductive and Digital to incremental signal conditioning.

  • Evaluation module for inductive (mod_ind):
    • 1 differential signal input
    • Input amplitude 60mV to 50 Vrms
    • Input frequency 120 kHz
  • Evaluation module for incremental encoders (mod_dig):
    • 3 differential signal traces
    • Input frequency 300 kHz depending on the version or 1.5MHz
Item Wert
Number of channels: ≤ 2
Size: 19" plug-in-module 100x100 mm
Temperature range: 0 ... +50 °C
In-/output value: Inkremente
Bedingung Wert
Operating temperature: 0 ... +50 °C
Storage temperature: 0 ... +60 °C
Relative humidity: 20 ... 65 %
Protection type: IP20 according to EN 60529

Shunt carrier card 4 channel 25A

The MCM-R04ABS-SHUNT25A Shuntträgerkarte is designed for project-specific applications of current shunts in high current paths, preferably in combination with the MCM-I08AII-BI. 4 Administered shunt values in different designs can this be installed. The max. Current per channel is 25 A, the power supply is done via power terminals, the voltage taps on four-wire technology are available on separate front terminals.

MCM-R04ABS SHUNT25A module is ideally suited to measure the current in the control device channel, such as at power outputs. She is best equipped for use in harsh environments. Application areas include control device tester, component test benches and HIL systems.

  • Four administrable current channels
  • Maximum load current 25 A
  • Shuntbauformen DO220 / MSR-3 / MSR-5 / WSL3637
  • 2x optionally, RH-5 / RH-25
  • Load power supply via power terminals type TOP 4GS 6 mm2 with screw
  • Pitch 6.35 mm
  • Messspannungsabgriff via terminals type S2L
  • Pitch 3.5
Item Wert
Number of channels: ≤ 8
Size: 19" plug-in-module 100x100 mm
In-/output value: Resistance
In-/output area: 0 ... 25 A
Bedingung Wert
Operating temperature: 0 ... +50 °C
Storage temperature: -20 ... +70 °C
Relative humidity: 20 ... 85 %
Protection type: IP20 according to EN 60529

Shunt carrier card 8-channel 10A

The MCM-R08ABS-SHUNT10A Shuntträgerkarte is designed for project-specific applications of current shunts in current paths, preferably in combination with the MCM-I08AII-BI. 8 administrable shunt values in different designs can this be installed. The max. Current per channel is 10 A, the power supply is done via power terminals, the voltage taps on four-wire technology are available on separate front terminals.

The MCM-R08ABS-SHUNT10A module is ideally suited for current measurements to control units channels such as in sensor inputs or the sensor supply and power outputs. She is best equipped for use in harsh environments. Application areas include control device tester, component test benches and HIL systems.

  • Eight administered stream channels
  • Maximum load current 10 A
  • Shuntbauformen DO220 / MSR-3 / MSR-5 / WSL3637
  • power supply via power terminals type BC / SC
  • 3.81 mm pitch
Item Wert
Number of channels: ≤ 8
Size: 19" plug-in-module 100x100 mm
In-/output value: Resistance
In-/output area: 0 ... 10 A
Bedingung Wert
Operating temperature: 0 ... +50 °C
Storage temperature: -20 ... +70 °C
Relative humidity: 20 ... 85 %
Protection type: IP20 according to EN 60529