MCM SYSTEM CASES

We offer numerous housing versions for our MCM modules - from the single-slot housing to the 84TE subrack.

The MCM system housings at a glance ...

Basic Rack 3U 84HP

Completely mounted and ready for connection 19 "rack for holding up to 16 MCM modules.

  • Subrack 3 U, 84 HP, t = 175 mm with rear panel, cover plates and mounting tabs
  • Power supply (60 - 260 VAC, 47 - 60 Hz) for the module supply, overvoltage category II
  • IEC power socket, fuse T 500 mA
  • 9-pin D-sub connector for optional configuration and data exchange via CAN
  • Integrated Backplane for Power Supply, High-speed CAN communication and the MCM modules
  • Mains connection cable 2 m
  • CAN connecting cable, 9-pin D-Sub 1.8m
  • CAN terminating resistor
  • MCM User Manual
  • Graphical User Interface MCM-ControlDesk
Item Wert
Size: 19"-system
Isolation voltage: ≤ 560 V
Temperature range: 0 ... +50 °C
Bedingung Wert
Operating temperature: 0 ... +50 °C
Storage temperature: -20 ... +70 °C
Relative humidity: 20 ... 85 %
Protection type: IP20 according to EN 60529

Basic Rack 3U 84HP high-voltage

Completely mounted and ready for connection 19 "rack with galvanically decoupled system ground to earth (800  VDC) for the recording of up to 16 MCM modules.

  • Subrack 3 U, 84 HP, t = 175 mm with rear panel, cover plates and mounting tabs
  • Power supply (230 VAC ±10 %, 50 Hz) for the module supply, overvoltage category II
  • IEC power socket, fuse T 500 mA
  • Optically isolated CAN transceiver
  • 9-pin D-sub connector for configuration and data exchange via CAN
  • Integrated Backplane for Power Supply, High-speed CAN communication and the MCM modules
  • mains connection cable 2 m
  • CAN connecting cable, 9-pin D-Sub 1.8 m
  • CAN terminating resistor
  • MCM User Manual
  • Graphical User Interface MCM-ControlDesk
Item Wert
Size: 19"-system
Isolation voltage: ≤ 800 V
Temperature range: 0 ... +50 °C
Bedingung Wert
Operating temperature:
Storage temperature:
Relative humidity:
Protection type: IP20 according to EN 60529

Userinterface

Over the surface of MCM-ControlDesk, the configuration and operation of the individual MCM-IO modules as well as the visualization of the measured data.

With the MCM-ControlDesk user interface all measured values and states of the MCM-I/O-Baugruppen can be easily visualized and stored.

  • Operation and configuration of all MCM-IO modules via a uniform user interface
  • Automatic detection of connected MCM-IO module
  • Limit monitoring of Kanaälen to undershoot and overshoot
  • Export of measured values in CSV files